• Saline flush
  • 0.25% Marcaine plain
  • 2mL heparin in a 3mL syringe at the end (uses 1.2mL)

minor instrument tray

9.6 port catheter

 

patient supine with arms in burrito roll

 

mayo: neutral zone with 11 and 15

saline in 10mL syringe

marcaine in 10mL syringe

3 snaps

1 mosquito

scissors

adson

debakey

syringe with needle from cath set

port and catheter connected

silver driving needle

dilator and silver sheath (sheath off)

non penetrating towel clamp

 

0 vicryl (x2)

3-0 vicryl

4-0 biosyn

 

steps

  1. prep and drape
  2. Half sheet then 4 sticky towels
  3. lap drape
  4. Light handles, bovie
  5. ultrasound cover and lube on transducer