Endometrial Ablation Device

NovaSure disposable device · NovaSure wand · Global endometrial ablation device · Bipolar endometrial ablation device · Thermal balloon catheter · Uterine balloon catheter

A single-use, pistol-grip wand with a long thin sheathSHEETHA covering that wraps around a structure; in procedures, a short hollow tube left in a blood vessel to pass catheters through.Full entry . Squeezing the handles opens a fan-shaped mesh electrode out of the tip that conforms to the uterine cavity, and a WIDTH dial on the handle reads the cavity width. A connecting cord carries the RF cable and suction tubing to the controller. The thermal balloon type is instead a catheter with a balloon on its end that holds a heating element.

1 photo

Tap the photo to zoom
Class
Supplies
On setups
1

On the table

What it does, the lengths it comes in and what experienced techs know about it.

  • What it’s for

    Global (whole-cavity) endometrial ablationab-LAY-shunA procedure that destroys a small area of tissue, often with heat or cold, to stop it from causing a problem.Full entry for heavy menstrual bleeding in patients who are done with childbearing, done blind without a hysteroscope. After the uterus is sounded and the cervix dilated, the wand goes through the cervix to the fundusFUN-dusThe rounded top or base of a hollow organ, most often the top of the uterus.Full entry , the mesh is opened and seated, and the surgeon reads the width off the dial for the circulator to key into the controller. The controller checks the cavity with carbon dioxideKAR-bun dy-OK-sideA gas made by the body's cells as waste, carried in the blood to the lungs and breathed out.Full entry , then ablates for about 90 seconds and stops on its own. The mesh is closed back into the sheathSHEETHA covering that wraps around a structure; in procedures, a short hollow tube left in a blood vessel to pass catheters through.Full entry and the wand removed. A thermal balloon catheter is passed until its tip touches the fundus, filled with sterile dextrose 5% in waterDEX-trose five per-SENT in WAH-terAn IV fluid of 5 grams of glucose in every 100 mL of water, written D5W.Full entry and heated for 8 to 10 minutes.

  • Lengths and variants

    NovaSure: 6 mm nominal tip diameter; the array treats cavities that sound 10 cm or less, with a cavity length of at least 4 cm and a cornu-to-cornu width of at least 2.5 cm. Thermal balloon: cervix dilated to 5 mm, balloon filled to 160 to 180 mm Hg and heated to 86.6 C (188 F).

  • What experienced techs know

    What techs who reach for it every day know about it.Pro

Through the case

In the order you meet it: before, during and after the case.

  • Before the case

    Inspection and testing

    What to check before it reaches the field.Pro

  • During the case

    Caution

    What not to do with it, and why.Pro

  • After the case

    Care and reprocessing

    How it is cleaned, checked and sent back to sterile.Pro

These notes are Pro, on every instrument. See Pro

Exam prep for this instrument

Know it on sight.

With Pro, for every instrument in the library. Cancel any time.

Or scrub in free: 5 questions a day.

FlashcardsThis one, back right before you would forget itPro
A practice test of suppliesEvery supplies instrument, the reason after eachPro
The 1 setup it is onA practice test and a timed exam for eachPro

On 1 setup

Every setup it is laid out on.

The list of setups

Every setup this instrument is laid out on, with photos of each table.

See Pro

Know this instrument?

Send a clearer photo, another name it goes by, or a fix for this page.

Send a photo or a fix

A photo of it on your tray, a name your OR calls it, or anything wrong on this page. Your email is only used to credit you. Submissions stay private and are reviewed by our team; accepted ones earn a Contributor credit here.

Drop your file here, or browse
5 sources
  1. Rock JA, Jones HW. Te Linde's Operative Gynecology. 10th ed. Chapter 15 (Principles of Electrosurgery as Applied to Gynecology), p. 294-295
  2. Rothrock JC. Alexander's Care of the Patient in Surgery. 17th ed. Chapter 14 (Gynecologic and Obstetric Surgery), p. 428
  3. Fuller JK. Surgical Technology: Principles and Practice. 8th ed. Chapter 23 (Gynecological and Obstetrical Surgery), p. 556
  4. Association of Surgical Technologists (Frey K, ed.). Surgical Technology for the Surgical Technologist. 4th ed. Chapter 15 (Obstetric and Gynecologic Surgery), p. 564
  5. hologic.com

The rest of this card is Pro.

The photos, the description, the uses and the lengths stay free. Pro opens the rest on every instrument: the 3D model, the notes from the table, where it is kept, every setup it is on, and practice.

Free, for good. No card.

  • All 3,323 instrument cards
  • Every General setup in full
  • 5 exam questions a day
  • Your own preference cards
Scrub in, free
Pro

Pass your exam. Know every case.

Everything in Free, plus:

  • All 298 setups in every specialty: back table, Mayo and every step
  • Practice that never runs out and full timed exams for the CST, TS-C, CRCST, CSPDT and CSFA, with the why behind every answer
  • Flashcards on any tray, timed to come back before you forget
  • Every instrument card in full: the 3D model, cautions, inspection, how to pass it
Every 4 weeksStudying for your exam? Cancel when you pass.
$12.99under 50¢ a day

Cancel any time from your account. Not worth it? Email us within 30 days of a charge for a refund, one per customer. Refund policy

Pro is also in the CSTSetup app, on the same account. Already have Pro? Log in